Title of article :
Thin film stress measurement by instrumented optical fibre displacement sensor
Author/Authors :
S. Chowdhury، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
6
From page :
4289
To page :
4294
Abstract :
Residual stress can adversely affect the mechanical, electronic, optical and magnetic properties of thin films. This work describes a simple stress measurement instrument based on the bending beam method together with a sensitive non-contact fibre optical displacement sensor. The fibre optical displacement sensor is interfaced to a computer and a Labview programme enables film stress to be determined from changes in the radius of curvature of the film–substrate system. The stress measurement instrument was tested for two different kinds of thin film, hard amorphous carbon nitride (CN) and soft copper (Cu) films on silicon substrates deposited by RF magnetron sputtering. Residual stress developed in 500 nm thick CN thin films deposited at substrate temperatures in the range 50–550 8C was examined and it was found that stress in CN films decreased from 0.83 to 0.44 GPa compressive with increase of substrate temperature. Residual stress was found to be tensile (121 MPa) for Cu films of thickness 1500 nm deposited at room temperature
Keywords :
stress measurement , Bending beam method , Carbon nitride , copper , Thin film