• Title of article

    Adhesion strength characterization of PVDF/HA coating on cp Ti surface modified by laser beam irradiation

  • Author/Authors

    A.A. Ribeiro، نويسنده , , L.G. Vaz، نويسنده , , A.C. Guastaldi، نويسنده , , J.S.C. Campos، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    5
  • From page
    10110
  • To page
    10114
  • Abstract
    Up to the moment, there is no standardized test for measuring the adhesion strength of polymeric coatings on titanium substrate modified by laser beam irradiation. The present work aimed to assess the adhesion strength of polyvinylidene fluoride (α-PVDF)/hydroxyapatite (HA) composite coating on commercially pure titanium (α-cp Ti) substrate surface modified by laser beam irradiation, using the three-point bending test. The preparation of coating was carried out by mixing α-PVDF pellets dissolved in dimethylacetamide (DMA) with HA/DMA emulsion. The mixture was poured onto the α-cp Ti sample and left to dry in an oven. Commercially pure titanium plates were coated with α-PVDF/HA composite film, in proportions of 100/00 (PVDF) and 60/40 (PVDF/HA) in weight. The Ti-PVDF/HA samples were subjected to the three-point bending test and analyzed by scanning electron microscopy. According to the results, PVDF and PVDF/HA coatings showed a good adhesion strength on α-cp Ti surface, since no detachment was observed.
  • Keywords
    Titanium , Laser beam irradiation , Hydroxyapatite , Coating , Biomaterial , Adhesion strength , Polyvinylidene fluoride
  • Journal title
    Applied Surface Science
  • Serial Year
    2012
  • Journal title
    Applied Surface Science
  • Record number