Author/Authors :
Hong Li، نويسنده , , Yang Wu، نويسنده , , Yunsheng Ge، نويسنده , , Si-Jia Jiang a، نويسنده , , Kai Gao، نويسنده , , Pengyun Zhang، نويسنده , , Lingxiang Wu، نويسنده , , Shiyi Chen، نويسنده ,
Abstract :
The purpose of this study was to determine the effect of the combination of hydroxyapatite (HA) and bioglass (BG) on polyethylene terephthalate (PET) artificial ligament graft osseointegration within the bone tunnel. The results of in vitro culturing of MC3T3-E1 mouse osteoblastic cells proved that this HA/BG composite coating can promote the cell compatibility of grafts. A rabbit extraarticular tendon-to-bone healing model was used to evaluate the effect of this composite coating on PET artificial ligaments in vivo. The final results demonstrated that HA/BG coating improved new bone formation at the graft-bone interface and increased the load-to-failure property of graft in bone tunnel compared to the control group at early time. The study has shown that HA/BG composite coating on the PET artificial ligament surface has a positive effect in the induction of artificial ligament osseointegration within the bone tunnel.
Keywords :
Polyethylene terephthalate , Hydroxyapatite , Bioglass , Osseointegration , Artificial ligament