    The paper describes the performance of an ammonia–water combined ejector–absorption cycle as refrigerator using two simple models. In the first an ejector draws vapour from an evaporator and discharges to a condenser. In the second, an ejector draws vapour from an evaporator and discharges to an absorber. The thermodynamics cycles and ejector operation on the temperature–entropy charts are shown. The thermodynamics of the combined ejector–absorption cycle are simulated by a suitable method and a corresponding computer code, based on analytic functions, describes the behaviour of the binary mixture NH3–H2O. It was found from the first model that the refrigerator (theoretical) coefficient of performance (COP) varied from 1.099 to 1.355 when the operation conditions were: generation temperature (237°C), condenser temperature (25.9–30.6°C), absorber temperature (48.6–59.1°C) and evaporator temperature (−1.1–7.7°C). In the second the theoretical COP vary from 0.274 to 0.382 when the operation conditions were: generation temperature (237°C), condenser temperature (91°C), absorber temperature (76.7–81°C) and evaporator temperature (−1.1–7.7°C).