Title of article
Use of two-phase loop thermosyphons for thermoelectric refrigeration: experiment and analysis
Author/Authors
J.S. Lee ، نويسنده , , S.H. Rhi، نويسنده , , C.N. Kim، نويسنده , , Y. Lee، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
10
From page
1167
To page
1176
Abstract
Reported are the results of an experimental and analytical (simulation) study on a thermoelectric refrigeration system employing two two-phase loop thermosyphons. The experimental results show that a heat transfer rates of up to about 29 W/°C m2 (the area based on the outside heat transfer area of the condenser sections) or about 5400 W/°C m2 (the area based on the heat transfer area of the Peltier element) at the average air temperature of the refrigerator of −4.6 °C, with an ambient outside air temperature of 25 °C, can be attainable under the forced convection heat transfer at the finned evaporator and condenser sections.
Keywords
Thermoelectric refrigeration , Two-phase loop thermosyphon , simulation , Peltier element