    Performance assessment of HCFC-22 window air conditioner retrofitted with R-407C

  • Author/Authors

    S. Devotta، نويسنده , , A.S. Padalkar، نويسنده , , N.K. Sane، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    13
  • From page
    2937
  • To page
    2949
  • Abstract
    This paper presents the experimental performance analysis of a 1.5 TR window air-conditioner, retrofitted with R-407C, as a substitute to HCFC-22. Experimental results showed that R-407C, for the operating conditions covered in this study, had lower cooling capacity in the range 2.1–7.9% with respect to HCFC-22. The coefficient of performance for R-407C was lower in the range 7.9–13.5%. The power consumption of the unit with R-407C was higher in the range 6–7% than HCFC-22. The discharge pressures for R-407C were higher in the range 11–13% than HCFC-22. This paper also presents simulation results of heat exchangers of an HCFC-22 window air conditioner retrofitted with R-407C. The simulation has been carried out using EVAP-COND, a heat exchanger model developed by National Institute of Standards and Technology, U.S.A. The simulated evaporator capacities are within ±3% of the experimentally measured cooling capacities for both refrigerants. Simulation results for R-407C and HCFC-22 are compared. The exit temperatures of R-407C are lower by 1.9 °C to 5.2 °C in the condenser and are higher by 3.2 °C to 3.8 °C in the evaporator than HCFC-22. Evaporating pressures of R-407C are higher by 4.5–5.3% as compared to HCFC-22. The pressure drops of R-407C are lower in both the evaporator and the condenser as compared to HCFC-22. The outlet temperatures of air for HCFC-22 and R-407C in both heat exchangers are nearly the same.
  • Keywords
    R-407C , performance , Cooling capacity , COP , measurement , Power consumption
  • Journal title
    Applied Thermal Engineering
  • Serial Year
    2005
  • Journal title
    Applied Thermal Engineering
  • Record number

    1026227