Title of article
Determination of metals in highly saline matrices by solid-phase extraction and slurry-sampling inductively coupled plasma-atomic emission spectrometry Original Research Article
Author/Authors
O Abollino، نويسنده , , M Aceto، نويسنده , , M.C Bruzzoniti، نويسنده , , E Mentasti، نويسنده , , C Sarzanini، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1998
Pages
6
From page
293
To page
298
Abstract
Matrix removal and preconcentration of metals from liquid samples were obtained with a solid-phase extraction/slurry-sampling procedure applied to inductively coupled plasma-atomic emission spectrometry (ICP-AES) detection. A polymeric, adsorbing resin (Amberlite XAD-2), dispersed in the sample, was used for total sorption of analytes previously complexed with a dithiocarbamate ligand. After filtration, the resin was recovered and re-dispersed by means of a non-ionic surfactant; metals retained were determined with the slurry-sampling technique. All parameters were optimised to yield a solution-like signal from the final dispersion.
Keywords
Slurry-sampling , ICP-AES , Preconcentration , Solid-phase extraction
Journal title
Analytica Chimica Acta
Serial Year
1998
Journal title
Analytica Chimica Acta
Record number
1027203