    Juan C. Vidal، نويسنده , , Esperanza Garcia، نويسنده , , Juan R. Castillo، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    10
  • From page
    213
  • To page
    222
  • Abstract
    A straightforward method for constructing cholesterol biosensors by entrapment of cholesterol oxidase within a polypyrrole (PPy) film electropolymerized in a flow system is proposed. This method enables adjustment of the biosensor characteristics and features low reagent consumption. Prior to use, the PPy film is overoxidized to provide it with anion-exclusion properties in order to minimize the interference of electroactive species such as ascorbic acid and uric acid. A comprehensive preliminary study of the influence of 2-propanol and Triton X-100 added to the cholesterol solution on the flow-injection determination of this substrate, and the effects of different experimental variables on the biosensor response and its selectivity against interfering electroactive species was carried out. The proposed cholesterol oxidase based biosensor, named Pt/PPy–ChOx, was applied to the determination of cholesterol in reference serum samples, and the results were consistent with certified values.
  • Keywords
    Polypyrrole electropolymerization , Cholesterol biosensor , Flow system , Cholesterol oxidase entrapment