Title of article :
Direct flow injection chemiluminescence determination of salicylamide Original Research Article
Author/Authors :
Y Fuster Mestre، نويسنده , , L.Lahuerta Zamora، نويسنده , , J Mart??nez Calatayud، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
5
From page :
159
To page :
163
Abstract :
A new direct flow injection chemiluminescence method is proposed for the determination of salicylamide, based upon the oxidation of the drug by potassium permanganate in dilute sulphuric acid. The calibration graph is linear over the range 20 ng ml−1 (30 limit of detection)–8 μg ml−1 salicylamide, with a relative standard deviation (n=50, 0.5 μg ml−1) of 1.7%. The average sample insertion rate is 142 h−1. The influence of relevant foreign compounds is found to be relatively slight. The method is applied to the determination of salicylamide in a pharmaceutical formulation and human urine.
Keywords :
Chemiluminescence , Flow injection analysis , Salicylamide , Permanganate , Pharmaceuticals