• Title of article

    Sensitive chemiluminescence aptasensor based on exonuclease-assisted recycling amplification Original Research Article

  • Author/Authors

    Sheng Cai، نويسنده , , Yanhua Sun، نويسنده , , Choiwan Lau، نويسنده , , Jianzhong Lu، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    6
  • From page
    137
  • To page
    142
  • Abstract
    We report herein an exonuclease-assisted aptamer-based target recycling amplification strategy for sensitive and selective chemiluminescence (CL) determination of adenosine. This aptasensor is based on target-induced release of aptamers from capture probes immobilized on the 96-well plate surface, and thus leading to a decreased hybridization with gold nanoparticle-functionalized reporter sequences followed by a CL signal. The introduction of exonuclease III catalyzes the stepwise removal of mononucleotides from 3′-hydroxyl termini of duplex DNAs of aptamers, liberating the adenosine. Therefore, a single copy of target adenosine can lead to the release and digestion of numerous aptamer strands from the 96-well plates and ultimately an enhanced sensitivity is achieved. Experimental results revealed that the exonuclease-assisted recycling strategy enabled the monitoring of adenosine with wide working ranges and low detection limits (LOD: 0.5 nM). This new CL strategy might create a novel technology for the detection of various targets and could find wide applications in the environmental and biomedical fields.
  • Keywords
    Chemiluminescence , Exonuclease III , Recycling amplification , Aptasensor
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2013
  • Journal title
    Analytica Chimica Acta
  • Record number

    1029127