• Title of article

    Polymerized hemin as an electrocatalytic platform for peroxynitriteʹs oxidation and detection Original Research Article

  • Author/Authors

    Serban F. Peteu، نويسنده , , Tiyash Bose، نويسنده , , Mekki Bayachou، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    8
  • From page
    81
  • To page
    88
  • Abstract
    Peroxynitrite (ONOO−) constitutes a major cytotoxic agent, implicated in a host of pathophysiological conditions, thereby stimulating a tremendous interest in evaluating its role as an oxidant in vivo. Some of the detection methods for peroxynitrite include oxidation of fluorescent probes, EPR spectroscopy, chemiluminescence, immunohistochemistry, and probe nitration; however, these are more difficult to apply for real-time quantification due to their inherent complexity. The electrochemical detection of peroxynitrite is a simpler and more convenient technique, but the best of our knowledge there are only few papers to date studying its electrochemical signature, or reporting amperometric microsensors for peroxynitrite. Recently, we have reported the use of layered composite films of poly(3,4-ethylenedioxythiophene) (PEDOT) and hemin (iron protoporphyrin IX) as a platform for amperometric measurement of peroxynitrite. The main goal herein is to investigate the intrinsic catalytic role of hemin electropolymerized thin films on carbon electrodes in oxidative detection of peroxynitrite. The electrocatalytic oxidation of peroxynitrite is characterized by cyclic voltammetry. The catalytic current increased as a function of peroxynitriteʹs concentration, with a peak potential shifting positively with peroxynitriteʹs concentration. The catalytic efficiency decreased as the scan rate increased, and the peak potential of the catalytic oxidation was found to depend on pH. We show that optimized hemin-functionalized carbon electrodes can be used as simple platforms for peroxinitrite detection and quantification. We report dose–response amperometry as an electroanalytical determination of this analyte on hemin films and we contrast the intrinsic hemin catalytic role with its performance in the case of the PEDOT–hemin as a composite matrix. Finally, we include some work extending the use of simple hemin films for peroxynitrite determination on carbon microfiber electrodes in a flow system.
  • Keywords
    Microelectrode , Flow injection analysis , Peroxynitrite , Electrocatalysis hemin , Iron protoporphyrin IX , Glassy carbon
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2013
  • Journal title
    Analytica Chimica Acta
  • Record number

    1029435