• Title of article

    Microwave-assisted extraction combined with gel permeation chromatography and silica gel cleanup followed by gas chromatography–mass spectrometry for the determination of organophosphorus flame retardants and plasticizers in biological samples Original Re

  • Author/Authors

    Yongqing Ma، نويسنده , , Kunyan Cui، نويسنده , , Feng Zeng، نويسنده , , Jiaxin Wen، نويسنده , , Hong Liu، نويسنده , , Fang Zhu، نويسنده , , Gangfeng Ouyang، نويسنده , , Tiangang Luan، نويسنده , , Zunxiang Zeng، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    7
  • From page
    47
  • To page
    53
  • Abstract
    An analytical method for the determination of 14 organophosphorus flame retardants (OPFRs), including halogenated OPFRs, non-halogenated OPFRs and triphenyl phosphine oxide (TPPO) in biological samples was developed using gas chromatography–mass spectrometry (GC/MS). Biological samples were extracted using microwave-assisted extraction (MAE) with hexane/acetone (1:1, v/v) as the solvent; then, a two-step clean-up technique, gel permeation chromatography (GPC) combined with solid phase extraction (SPE), was carried out before GC/MS analysis. Experimental results showed that the developed method efficiently removed the lipid compounds and co-extract interferences. Moreover, using the relatively “narrow” column (with an i.d. of 10 mm) significantly decreased the elution volume and, therefore, prevented the loss of the most volatile OPFRs, especially trimethyl phosphate (TMP) and triethyl phosphate (TEP). The method detection limits (MDLs) for OPFRs in the biological samples ranged from 0.006 to 0.021 ng g−1 lw, and the recoveries were in the range of 70.3–111%, except for TMP (38.9–55.6%), with relative standard deviations (RSDs) of less than 14.1%. The developed method was applied to determine the amount of the target OPFRs in biological samples (i.e., fish and domestic birds) that were collected from the Pearl River Delta (PRD) region in southern China. Of the 14 OPFRs, tri-n-butyl phosphate (TnBP), tris(2-chloroethyl) phosphate (TCEP), tris(chloropropyl) phosphate (TCPP) and tributoxyethyl phosphate (TBEP) were present in all of the biological samples that were analyzed, and dominated by TnBP, TCEP and TBEP. The concentrations of OPFRs in the biological samples that were collected from the PRD region were higher than those reported in other locations.
  • Keywords
    Microwave-assisted extraction , Gel permeation chromatography , Solid phase extraction , Gas chromatography–mass spectrometry , Biological sample , Organophosphorus flame retardants and plasticizers
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2013
  • Journal title
    Analytica Chimica Acta
  • Record number

    1029503