Abstract :
The purities of the widely-used herbicide glyphosate (N-(phosphonomethyl)glycine), and the insecticide profenofos (O-(4-bromo-2-chlorophenyl) O-ethyl S-propyl phosphorothioate) were determined by 1H and 31P quantitative nuclear magnetic resonance (QNMR) spectrometry using an internal standard. QNMR does not need a standard reference of the same target analyte, in contrast to chromatographic methods, but only a compound containing the nucleus of interest. Sodium acetate and sodium phosphate of known purity were chosen as internal standards for 1H NMR and 31P NMR), respectively for the water soluble glyphosate and a single internal standard, trimethyl phosphate for both 1H and 31P NMR quantitative analysis of the organic soluble profenofos. These standards have NMR peaks that do not interfere with those of the analyte, they are chemically inert and are soluble in the deuterated solvent. The average purity of glyphosate obtained by 1H NMR (97.07%, σ=0.68) agreed with that by 31P NMR (96.53%, σ=0.90; ANOVA, P=0.074) for the five batches provided by the manufacturer according to the procedures for chemical registration in Australia. The standard deviations of seven independent analyses of a single batch by 1H NMR and 31P NMR were σ=0.24% and σ=0.33%, respectively, values which confirm the exceptional precision of the method. The purity of profenofos by 1H NMR (94.63%, σ=0.14) also agreed with that by 31P NMR (94.62%, σ=0.59; ANOVA, P=0.97). Uncertainty budgets for the measured purities of glyphosate and profenofos show that the uncertainty in the purity of the internal standard is a major contributor to the uncertainty of the result. NMR was also used to establish the impurity profile of both compounds, and quantify the impurities present.
Keywords :
31P NMR , Glyphosate , Profenofos , Purity measurements , Quantitative NMR spectrometry , Agrochemicals
Journal title :
Analytica Chimica Acta
Serial Year :
2002
Journal title :
Analytica Chimica Acta
Record number :
1030051
Link To Document :
بازگشت