Title of article
Determination of free chlorine based on anodic voltammetry using platinum, gold, and glassy carbon electrodes Original Research Article
Author/Authors
Fumihiro Kodera، نويسنده , , Minoru Umeda، نويسنده , , Akifumi Yamada، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
6
From page
293
To page
298
Abstract
The oxidation of free chlorine on platinum, gold, and glassy carbon disk electrodes has been investigated by using anodic voltammetry to determine the free-chlorine concentration. The voltammetric curves exhibited well-defined anodic peaks. The influences of pH, free-chlorine concentration, and potential sweep rate on the electrode response were investigated. The results show that the measurement of the oxidation peak current can be used as the basis for a simple, accurate, and rapid method for the determination of ClO−, within a concentration range of 4–400 mg Cl l−1. The results of this method were in good agreement with those obtained by iodometric titration. Differential pulse voltammetry has also been examined, resulting in an improved sensitivity at a concentration of 1.0 mg Cl l−1.
Keywords
Free chlorine , Glassy carbon electrode , Platinum , Anodic voltammetry
Journal title
Analytica Chimica Acta
Serial Year
2005
Journal title
Analytica Chimica Acta
Record number
1030659
Link To Document