Title of article
Flow analysis of p-aminophenyl phosphate with a gold nanoelectrode ensemble based detector Original Research Article
Author/Authors
Tsung-Huang Hsia، نويسنده , , Kuo-Tang Liao، نويسنده , , Hsuan-Jung Huang، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
5
From page
315
To page
319
Abstract
An alkaline phosphatase (AP) immobilized gold nanoelectrode ensemble (GNEE) was fabricated by electroless deposition of Au3+ onto the nanopores (d = 50 nm) of polycarbonate membranes and modifying the surface of GNEE successively with a self-assembled monolayer (SAM) of 2-aminoethanethiol, an alkaline phosphatase (AP) layer and a porous film of poly(4-vinylpyridine-co-styrene) (PVP). Performance of the AP–GNEE was studied by monitoring the current responses from the injection of p-aminophenyl phosphate (p-APP) into a flow injection analysis (FIA) system. Optimal conditions such as concentration of AP for immobilization, pH of carrier solution, potential applied for the analysis of p-APP were studied. Calibration graph over a broad dynamic concentration range (0.1 μM to 1.0 mM) gave satisfactory linearity (R2 = 0.986) and a very low detection limit (0.1 μM) confirming the applicability and superiority of the AP–GNEE for p-APP analysis.
Keywords
Electroless deposition , Alkaline phosphatase , Gold nanoelectrode , Flow analysis
Journal title
Analytica Chimica Acta
Serial Year
2005
Journal title
Analytica Chimica Acta
Record number
1030662
Link To Document