Title of article :
A simple and rapid method for measuring dissolved oxygen in waters with gold microelectrode Original Research Article
Author/Authors :
You-Peng Chen، نويسنده , , Shao-Yang Liu، نويسنده , , Han-Qing Yu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
5
From page :
249
To page :
253
Abstract :
Dissolved oxygen (DO) is an essential indicator in chemical, biological and biochemical processes and needs to be rapidly measured in many cases. In this work, a rapid, sensitive and simple electrochemical method, first derivative linear sweep voltammetry (FD-LSV), was established for the determination of DO. The peak height of FD-LSV was found to be influenced by scan rate and microelectrode surface area. An empirical formula was proposed to describe the relationship between the FD-LSV peak height and the influencing factors. Compared with other electrochemical methods for DO determination, the FD-LSV method needed lesser time and was more accurate. This method was successfully applied for the determination of the DO levels of various environmental water samples.
Keywords :
Dissolved oxygen , Microelectrode , Scan rate , Surface area , Water , First derivative linear sweep voltammetry
Journal title :
Analytica Chimica Acta
Serial Year :
2007
Journal title :
Analytica Chimica Acta
Record number :
1031126
Link To Document :
بازگشت