• Title of article

    Comparative study of robustness between micellar electrokinetic capillary chromatography and high-performance liquid chromatography using one-variable-at-a-time and a new multi-variable-at-a-time approach Original Research Article

  • Author/Authors

    Rade Injac، نويسنده , , Marija Boskovic، نويسنده , , Nina Kocevar، نويسنده , , Tomaz Vovk، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    12
  • From page
    150
  • To page
    161
  • Abstract
    Micellar electrokinetic capillary chromatography and reverse-phase liquid chromatography methods were developed in order to perform robustness testing to determine the caffeine content in beverages. Both methods were fully validated and two different robustness approaches were applied. One-variable-at-a-time (OVAT) approach at eleven levels (0; ±1; ±2; ±3; ±4; ±5 units) was carried out and compared with multi-variable-at-a-time (MVAT) approach at three levels (±1 unit per investigated parameter). Four analysts in two laboratories on two capillary electrophoresis and two RPLC equipments have tested the samples. Robustness was statistically analyzed using peak area, migration or retention time, symmetry, and resolution of caffeine and sulfacetamide as internal standard, and presented as R.S.D. values. The RPLC method was found to be more sensitive than the MEKC method. Both methods showed acceptable robustness level for OVAT approach, whilst MEKC method was more robust when the determination of real samples coming from different beverages was based on the MVAT approach.
  • Keywords
    robustness , Ruggedness , Micellar electrokinetic capillary chromatography , High-performance liquid chromatography , Multi-variable-at-a-time approach , One-variable-at-a-time approach
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2008
  • Journal title
    Analytica Chimica Acta
  • Record number

    1031751