Title of article :
Flow injection biamperometric determination of chloramphenicol and related nitro compounds by on-line chemical photodegradation Original Research Article
Author/Authors :
J.A.Garc??a Bautista، نويسنده , , J.V.Garc??a Mateo، نويسنده , , J.Mart??nez Calatayud، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
10
From page :
141
To page :
150
Abstract :
An unsegmented continuous-flow assembly for the determination of chloramphenicol is proposed. The determination is based on the on-line photodegradation of the drug in an NH4+/NH3 buffer at pH 10.4 by using a photoreactor consisting of a 697 cm long × 0.8 mm ID piece of PTFE tubing coiled around an 8 W low-pressure mercury lamp. Photodegraded chloramphenicol is detected by photolytic cleavage of nitrite from the parent compound as well as by organic oxidizing photofragments, and their subsequent reaction with iodide ion, which is monitored biamperometrically. Triiodide thus formed is detected in excess iodide solution by polarizing two platinum electrodes at 100 mV. The calibration graph is linear up to 8 mg l–1 chloramphenicol; the limit of detection is 0.05 mg l–1, the relative standard deviation is 0.4% (for 25 replicates of 10 mg l–1 drug) and the throughput 68 samples h–1. The proposed method was used to determine chloramphenicol in commercially available pharmaceutical formulations and human urine.
Keywords :
Pharmaceutical and clinical analyses , Photodegradation , Biamperometry , Flow injection analysis , Chloramphenicol
Journal title :
Analytica Chimica Acta
Serial Year :
2000
Journal title :
Analytica Chimica Acta
Record number :
1031813
Link To Document :
بازگشت