Title of article
Fluoroborate ion sensitive PVC membrane electrode based on chloro[tetra(m-amino-phenyl)porphinato]-manganese as neutral carrier Original Research Article
Author/Authors
Xiao-Bing Zhang، نويسنده , , Can-Cheng Guo، نويسنده , , Li-Xin Jian، نويسنده , , Guoli Shen، نويسنده , , Ru-Qin Yu، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
7
From page
227
To page
233
Abstract
A poly(vinyl chloride) (PVC) membrane electrode based on chloro[tetra(m-amino-phenyl)porphinato]-manganese (T(m-NH2)PPMnCl) and 2-nitrophenyl octyl ether (o-NPOE) in the composition 3:65:32 [T(m-NH2)PPMnCl:o-NPOE:PVC] exhibits Nernstian response to fluoroborate ion in the concentration range 5.1×10−7–1.0×10−1 mol l−1, with a wide working pH range from 5.3 to 12.1, and a fast response time of 15 s. The electrode shows good selectivity towards BF4− with respect to common coexisting ions, which is better than that of the electrode reported in the literature. Several electroactive materials and solvent mediators have been compared and the experimental conditions optimized. The electrode is applied to the determination of fluoroborate in electroplating solution samples with satisfactory results.
Keywords
Neutral carrier , Fluoroborate PVC membrane electrode
Journal title
Analytica Chimica Acta
Serial Year
2000
Journal title
Analytica Chimica Acta
Record number
1031960
Link To Document