• Title of article

    Determination of hydrogen peroxide using glassy carbon and graphite/polyester composite electrodes modified by vanadium-doped zirconias Original Research Article

  • Author/Authors

    Antonio Doménech، نويسنده , , Javier Alarc?n، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    12
  • From page
    11
  • To page
    22
  • Abstract
    Synthetic monoclinic and tetragonal vanadium-doped zirconias (VZrO2) with vanadium loading ranging from 0.5 to 15 mol% are used to modify glassy carbon and graphite/polyester composite electrodes able to detect oxygen and hydrogen peroxide in neutral aqueous media. Electrodes modified by monoclinic VZrO2 decrease the overpotential for the reduction of oxygen and hydrogen peroxide in neutral and alkaline media and enhance their reduction currents with respect to unmodified carbon electrodes. This is associated to seven-coordinated vanadium centers isomorphously substituting zirconium ones in the ZrO2 lattice. The catalytic effect shows site-selectivity, since it is almost entirely absent in tetragonal VZrO2 in which eight-coordinated vanadium sites exists. Under optimized conditions using differential pulse detection mode, the height of the cathodic catalytic current peak is directly proportional to the hydrogen peroxide concentration over the concentration range 5–400 μM with a sensitivity of 170 μA/mM at pH 10.0. The detection limit (3σ) is calculated as 0.9 μM.
  • Keywords
    Electrocatalysis , Site-selectivity , Hydrogen peroxide , Vanadium-doped , Zirconias
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2002
  • Journal title
    Analytica Chimica Acta
  • Record number

    1032726