Cytochrome c was immobilized on a mixed-thiol (mercaptoundecanoic acid/mercaptoundecanol) modified gold electrode (MUA:MU/cyt c electrode). Characterization of the cyt c electrode showed a quasi-reversible, electrochemical redox behavior with a formal potential of −13±5 mV (versus Ag/AgCl) for the surface adsorbed protein and 3±5 mV for covalently immobilized cyt c. The heterogeneous electron transfer rate constants were determined to be about 70 and 40 s−1 for both states of the protein, respectively. They were found to be significantly higher than those of pure MUA-modified cyt c electrodes (MUA/cyt c electrodes). The interaction of superoxide radicals (O2radical dot−) with the (MUA:MU)/cyt c electrode was characterized and used for an amperometric O2radical dot− detection. The influence of H2O2 and uric acid on the sensor signal was investigated. The sensitivity of the (MUA:MU)/cyt c electrode to O2radical dot− was significantly improved compared with that of the MUA/cyt c electrode. Based on a kinetic model for the superoxide detection system, a new calibration method was established. This simple and fast method used the spontaneous dismutation of KO2 and was compared with the enzymatic superoxide generation system using xanthine oxidase.