Title of article :
Determination of trace levels of mercury in water samples based on room temperature phosphorescence energy transfer Original Research Article
Author/Authors :
Blanca San Vicente de la Riva، نويسنده , , Jose M. Costa-Fernandez، نويسنده , , Wei Jun Jin، نويسنده , , Rosario Pereiro، نويسنده , , Alfredo Sanz Medel، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
A novel method has been developed for the sensitive determination of mercury in aqueous media by room temperature phosphorescence (RTP). The measurement principle is based on the energy transfer (ET) from a phosphor molecule (acting as a donor) to a Hg-sensitive dye (acceptor). To our acknowledgment this is the first RTP method for mercury measurement developed so far. α-Bromonaphthalene (BrN) was selected as the phosphorescent donor molecule (BrN can produce significant RTP emission in aqueous media in a β-cyclodextrin rigid microenvironment without deoxygenation).
The absorption spectrum of the complex formed between mercury and the dithizone dye possesses a desirable spectral overlap with the RTP emission spectrum of the donor (BrN), giving rise to a nonradiative ET from the phosphor molecules to the mercury complex. An increase in the concentration of Hg(II) causes an increase on the concentration of the dithizone complex (acceptor) with the subsequent increase of the absorbance and, therefore, resulting in a decrease of the RTP emission. Both, RTP intensities and triplet lifetimes of the BrN decreased with increases on the Hg(II) concentration.
Possible interferences present in natural waters, including different cations and anions, which could affect the analytical response, were evaluated and the analytical performance characteristics investigated. The use of phosphorescence measurements (low background noise signals) resulted in an improvement on the sensitivity of the Hg(II) detection higher than five times as compared to the molecular absorption spectrophotometric method for Hg(II) detection based on dithizone as Hg-indicator. A detection limit (D.L.) of 14 ng ml−1 of Hg(II) was obtained by RTP with a precision of ±4.8% for five replicates of 300 ng ml−1 of Hg(II). The usefulness of the method was successfully evaluated by the determination of Hg(II) in spiked natural water samples.
Keywords :
Dithizone , ?-Bromonaphthalene , Room temperature phosphorescence , Energy transfer , Mercury
Journal title :
Analytica Chimica Acta
Journal title :
Analytica Chimica Acta