Title of article :
In situ osmotic analyzer for the year-long continuous determination of Fe in hydrothermal systems Original Research Article
Author/Authors :
Thomas P. Chapin، نويسنده , , Hans W. Jannasch، نويسنده , , Kenneth S. Johnson، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
10
From page :
265
To page :
274
Abstract :
A submersible osmotically pumped analyzer (Fe-OsmoAnalyzer) has been adapted for the long-term continuous high resolution monitoring of iron(II) and (III) in deep-sea hydrothermal vents. Ferrozine is used as the colorimetric reagent. The detection limit for our analyzer is 0.1 μM for a 0.7 cm pathlength with a linear response up to 50 μM. The Fe-OsmoAnalyzer uses periodic injections of standards and blanks to self calibrate and can operate unattended for over a year collecting data every 15 min. The Fe-OsmoAnalyzer was field tested during a 6 week test deployment at 900 m in Monterey Bay and a year-long deployment at 1100 m off the coast of Hawaii. A second year-long deployment in a low temperature hydrothermal vent on the Juan de Fuca Ridge provided high resolution continuous monitoring of Fe and was able to distinguish tidally influenced fluctuations in Fe concentrations.
Keywords :
In situ , Seawater , Long-term , Hydrothermal , Osmotic pumps , Iron determination