Title of article :
A sensitive mediator-free tyrosinase biosensor based on an inorganic–organic hybrid titania sol–gel matrix Original Research Article
Author/Authors :
Ting Zhang، نويسنده , , Bozhi Tian، نويسنده , , Jilie Kong، نويسنده , , Pengyuan Yang، نويسنده , , Baohong Liu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
8
From page :
199
To page :
206
Abstract :
A novel inorganic–organic hybrid titania sol–gel nanocomposite film was prepared to fabricate a sensitive tyrosinase biosensor for the amperometric detection of trace phenolic compounds without additional electron mediators. Acetylacetone worked as a complexing ligand to chelate with Ti atom in the synthesis process, and the pH of the titania solution could be adjusted to the value which was optimum for retaining tyrosinase activity and such a membrane was stably attached on to the surface of a glassy carbon electrode (GCE). This titania matrix could supply a good environment for enzyme loading, which resulted in a high sensitivity of 15.78 μA μM−1 cm−2 for monitoring phenols with a detection limit of 1×10−8 M at a signal-to-noise ratio of 3. The TiO2 sol–gel derived biosensor exhibited a fast response less than 10 s and a good stability for more than 2 months.
Keywords :
Tyrosinase biosensor , Acetylacetone , Hybrid TiO2 sol–gel
Journal title :
Analytica Chimica Acta
Serial Year :
2003
Journal title :
Analytica Chimica Acta
Record number :
1033644
Link To Document :
بازگشت