Title of article :
Application of supported liquid membrane probe for extraction and preconcentration of organotin compounds from environmental water samples Original Research Article
Author/Authors :
Ewa Cukrowska، نويسنده , , Luke Chimuka، نويسنده , , Hermogène Nsengimana، نويسنده , , Valerie Kwaramba، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
7
From page :
141
To page :
147
Abstract :
The new supported liquid membrane (SLM) extraction probe (SLMP) was developed and optimized for extraction and preconcentration of organotin (OT) compounds from environmental water samples. SLMP is much simpler configuration than traditional SLM systems. The use of stirring allows the same sample to be extracted many times with higher extraction efficiency from smaller sample size. The SLMP was used to extract organotin compounds from aqueous solution to organic solvent (isooctane) followed by determination of organotin species by gas chromatography. The SLM probe extraction was optimized for extraction time, stirring rate, the geometry of the system, and ionic strength of the sample. The extraction efficiencies obtained were 63–94% for deionised water and 52–89% for sea water. The detection limit of the method ranged from 0.5 μg for triphenyltin to 1.5 μg for monobutyltin. The optimized procedure was applied for the speciation study of OT compounds in environmental water samples.
Keywords :
Supported liquid membrane extraction , Preconcentration , Organotin compounds speciation , Membrane probe
Journal title :
Analytica Chimica Acta
Serial Year :
2004
Journal title :
Analytica Chimica Acta
Record number :
1034343
Link To Document :
بازگشت