Title of article :
Stability of workroom air volatile organic compounds on solid adsorbents for thermal desorption gas chromatography Original Research Article
Author/Authors :
Jon Volden، نويسنده , , Yngvar Thomassen، نويسنده , , Tyge Greibrokk، نويسنده , , Syvert Thorud، نويسنده , , Paal Molander، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
9
From page :
263
To page :
271
Abstract :
The storage stability of the occupationally frequently occurring compounds, methylethylketone, methylisobutylketone, benzene, toluene, tetrachloroethylene, n-butylacetate, α-pinene, β-pinene, limonene and n-decane, has been investigated on the adsorbents Tenax TA, Chromosorb 106 and Carbotrap using thermally desorbable tube type samplers, commonly utilized in ambient and workroom atmospheric measurements. Fifty and 500 ng of each compound were loaded on the various adsorbents tubes, stored at both ambient (20 °C) and refrigerated (4 °C) temperatures and analysed by means of thermal gas chromatography with mass spectrometric detection on days 0, 7, 14 and 28 after exposure. A 90% storage recovery was chosen as acceptance criteria for storage stability, and statistical testing by Studentʹs t-test, analysis of variance and Bonferroni post hoc tests were employed to investigate the effect of the categorical variables storage time, storage temperature and analyte loading on the different adsorbents. Chromosorb 106 showed the overall best behaviour with recoveries of 90% or better for all analytes during the 28-day test period. Tenax TA and Carbotrap yielded lower recoveries and were more influenced by variations in storage time, storage temperature and analyte loading. Refrigerated temperatures were best avoided for storage on Tenax TA, but may increase the recovery of some compounds on Carbotrap (e.g. n-butylacetate). The blank build-up on the adsorbents was also investigated, and Carbotrap and Tenax TA showed no signs of artefact development over time. Chromosorb 106, however, contained inherently more artefacts that build up over time, which in spite of the excellent storage capability, may limit its use in field studies where long storage times are normal.
Keywords :
Solid adsorbents , Thermal desorption , Tenax TA , Carbotrap , Chromosorb 106 , Air sampling , Storage stability , Blank build-up , Volatile organic compounds (VOCs)
Journal title :
Analytica Chimica Acta
Serial Year :
2005
Journal title :
Analytica Chimica Acta
Record number :
1034517
Link To Document :
بازگشت