Title of article :
High speed liquid chromatography for in-process control of rifabutin Original Research Article
Author/Authors :
Domingo Blanco Gomis، نويسنده , , Noé S?nchez N??ez، نويسنده , , Elena Andrés Garc?a، نويسنده , , Pilar Arias-Abrodo، نويسنده , , Miguel Bayod Jasanada، نويسنده , , M?. Dolores Gutiérrez ?lvarez، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
6
From page :
105
To page :
110
Abstract :
A fast HPLC method has been developed for simultaneous determination of rifabutin and its synthesis precursors. The analytes are separated in 1.8 min by means of a Kromasil 100 C18 column (50 mm × 2.1 mm i.d., 3.5 μm) at 30 °C. The mobile phase (A: 5 mM KH2PO4 adjusted to pH 6.5 with KOH; B: acetonitrile) was pumped at a flow rate of 0.4 ml min−1 according to the fast gradient mode: 0 min, 58% B; 0–0.4 min, 95% B. Detection was by ultraviolet absorbance at 275 nm. The method was validated in accordance with the International Conference on Harmonisation (ICH) guidelines and good accuracy, intermediate precision (≤4.6%) and linearity in the range 5–50 mg l−1 were observed for all compounds. This method is sensitive (limits of detection ranged between 0.1 and 0.3 mg l−1) and selective to quantify rifabutin and its synthesis precursors and could be used for in-process control.
Keywords :
High speed HPLC , In-process control , Rifabutin
Journal title :
Analytica Chimica Acta
Serial Year :
2005
Journal title :
Analytica Chimica Acta
Record number :
1034537
Link To Document :
بازگشت