Title of article :
Liquid chromatographic tandem mass spectrometric determination of trandolapril in human plasma Original Research Article
Author/Authors :
Constantinos Pistos، نويسنده , , Maria Koutsopoulou، نويسنده , , Irene Panderi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
A liquid chromatographic tandem mass spectrometric method for the determination of trandolapril in human plasma has been developed and fully validated. The article describes, in detail, the bioanalytical procedure and summarizes the validation results obtained. The samples were extracted using HLB Oasis solid-phase extraction cartridges. The chromatographic separation was performed on X-Terra C8 MS column (150 mm × 4.6 mm i.d., 5 μm particle size) using a mobile phase consisting of acetic acid 20 mM and triethylamine 4.3 mM/acetonitrile (40:60 (v/v)), pumped isocratically at 0.35 ml/min.
The analytes were detected using a micromass quattro micro triple quadrupole mass spectrometer with positive electrospray ionization in multiple reaction-monitoring (MRM) mode. Tandem mass spectrometric detection enabled the quantitation of trandolapril down to 2.0 ng/ml. Calibration graphs were linear (r better than 0.996, n = 9) in the concentration ranges 2.0–750 ng/ml and the intra- and inter-day R.S.D. values were less than 3.83 and 3.86% for trandolapril.
Keywords :
Human plasma , Tandem mass spectrometry , Trandolapril
Journal title :
Analytica Chimica Acta
Journal title :