Abstract :
This paper describes a stripping voltammetric method for the determination of aluminum as contaminant in dialysis concentrates. It is based on the adsorptive deposition of the complex Al-1,2-dihydroxyanthraquinone-3-sulfonic acid (DASA) at the hanging mercury drop electrode (HMDE) at −0.9 V (versus Ag/AgCl) and its cathodic stripping during the potential scan. The method was optimized concerning the main electrochemical parameters that influence the voltammetric determination in highly saline solutions (sample dilution factor, deposition time and DASA concentration). The linear range for the measurements was from