Title of article :
Food safety evaluation: Detection and confirmation of chloramphenicol in milk by high performance liquid chromatography-tandem mass spectrometry Original Research Article
Author/Authors :
Rebecca S. Nicolich، نويسنده , , Eduardo Werneck-Barroso، نويسنده , , Marlice A. S?poli Marques، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
6
From page :
97
To page :
102
Abstract :
A simple and rapid procedure for extraction of chloramphenicol (CAP) in milk and analysis by high-performance liquid chromatography coupled with quadrupole mass spectrometry in tandem was developed. The method consisted of one step of liquid–liquid extraction using ethyl acetate and acidified water (10 mmol L−1 formic acid) and HPLC-MS/MS detection. CAP-D5 was used as internal standard. The method was validated according to Commission Decision 2002/657/EC. The calibration curves were linear, with typical r2 values higher than 0.98. Absolute recovery of CAP from milk proved to be more than 95%, however CAP-D5 absolute recovery was 75%. The method was accurate and reproducible, being successfully applied to the monitoring of CAP in milk samples obtained from the Brazilian market. Decision limit (CCα) was 0.05 ng mL−1 and detection capability (CCβ) was 0.09 ng mL−1.
Keywords :
Chloramphenicol , Antibiotic , High performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) , Food control
Journal title :
Analytica Chimica Acta
Serial Year :
2006
Journal title :
Analytica Chimica Acta
Record number :
1035788
Link To Document :
بازگشت