Title of article :
Electrochemical behaviour of isatin at a glassy carbon electrode Original Research Article
Author/Authors :
Victor C. Diculescu، نويسنده , , Sunita Kumbhat، نويسنده , , Ana Maria Oliveira Brett، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
The electrochemical behavior of isatin – a molecule with a broad range of applications in synthetic, biological and clinical activity – has been investigated over a wide pH range at a glassy carbon electrode (GCE) using cyclic, square wave and differential pulse voltammetry. The oxidation of isatin is an irreversible process, pH dependent and occurs with the formation of a main oxidation product that strongly adsorbs on the electrode surface. The reduction of isatin is also a pH dependent irreversible process. Cyclic voltammograms show two consecutive charge transfer reactions. The diffusion coefficient of isatin was calculated in pH 7.0 phosphate buffer to be D0 = 4.9 × 10−7 cm2 s−1. The limit of detection obtained in a solution of pH 7.0 phosphate buffer was LOD = 0.194 μM, based on three times the noise level.
Keywords :
Isatin , Oxidation , Reduction , Voltammetry , Indole
Journal title :
Analytica Chimica Acta
Journal title :
Analytica Chimica Acta