Flow injection chemiluminescence determination of nitrofurazone in pharmaceutical preparations and biological fluids based on oxidation by singlet oxygen generated in N-bromosuccinimide–hydrogen peroxide reaction Original Research Article
Author/Authors
Jianxiu Du، نويسنده , , Liang-Hao Huang، نويسنده , , Yinhuan Li، نويسنده , , Jiuru Lu، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
5
From page
98
To page
102
Abstract
A simple flow injection chemiluminescence (FI-CL) method was proposed for the determination of nitrofurazone. Strong CL signal was generated during the reaction of nitrofurazone with H2O2 and N-bromosuccinimide (NBS) in alkaline condition. The CL signal was proportional to the nitrofurazone concentration in the range 1.0 × 10−7 to 1.0 × 10−5 g mL−1. The detection limit was 2 × 10−8 g mL−1 nitrofurazone and the relative standard deviation was less than 4% (6.0 × 10−6 g mL−1 nitrofurazone, n = 11). The proposed method was successfully applied to the determination of nitrofurazone in compound furacillin nasal drops, human plasma and urine samples. The CL reaction mechanism was also discussed briefly. Singlet oxygen generated in the reaction between H2O2 and NBS was suggested to be participated in the CL reaction.
Keywords
Nitrofurazone , Chemiluminescence , Flow injection , Singlet oxygen