Title of article :
Chemiluminescence detection of organic peroxides in a two-phase system Original Research Article
Author/Authors :
Stefan Baj، نويسنده , , Tomasz Krawczyk، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
Potential application of chemiluminescence (CL) reaction of luminol for detection of organic peroxides by HPLC post-column reaction using an immiscible apolar eluent (hexane) with aqueous solution of luminol has been proposed. The positive influence of the addition of an anionic surface-active agent—sodium dodecyl sulphate (SDS) to the luminol solution on the CL intensity has been observed. The sensitivity of the method is greater for peroxyacid and hydroperoxide tested, and lesser for diacyl peroxide as compared to system with polar eluent miscible with solution of luminol. Our interpretation of observed results based on the extraction efficiency, CL kinetics and microemulsion formation has been suggested.
Keywords :
Chromatography chemiluminescence , Organic peroxides , Luminol
Journal title :
Analytica Chimica Acta
Journal title :
Analytica Chimica Acta