Title of article :
AChE biosensor based on zinc oxide sol–gel for the detection of pesticides Original Research Article
Author/Authors :
Ravi Sinha، نويسنده , , Mallikarjunarao Ganesana، نويسنده , , Silvana Andreescu، نويسنده , , Lia Stanciu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
5
From page :
195
To page :
199
Abstract :
Zinc oxide has been used as a matrix for immobilization of acetylcholinesterase (AChE) and detection of the pesticide paraoxon. The immobilized enzyme retained its enzymatic activity up to three months when stored in phosphate buffered saline (pH 7.4) at 4 °C. An amperometric biosensor for the detection of paraoxon was designed. The biosensor detected paraoxon in the range 0.035–1.38 ppm and can be used to detect other AChE inhibiting organophosphate pesticides.
Keywords :
Pesticide biosensor , Paraoxon , Acetylcholinesterase , Zinc oxide , Sol–gel
Journal title :
Analytica Chimica Acta
Serial Year :
2010
Journal title :
Analytica Chimica Acta
Record number :
1038174
Link To Document :
بازگشت