Title of article
Mode I fracture toughness of an adhesively bonded composite–composite joint in a cryogenic environment
Author/Authors
R.J. Melcher، نويسنده , , W.S. Johnson، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
6
From page
501
To page
506
Abstract
To determine the effect of cryogenic temperature on the adhesive fracture toughness of an adhesively bonded joint with composite adherends, monotonic mode I adhesive fracture toughness tests were performed at liquid nitrogen temperature (−196 °C) and at room temperature (27 °C). From these experimental tests, the critical strain energy release rate for both test temperatures was evaluated for the selected bonded joint system constructed of carbon-BMI adherends bonded with AF-191M film adhesive. Experimental results exhibit reduced adhesive fracture toughness at the cryogenic temperature and a profound difference in fracture mode.
Keywords
A. Adhesive joints , A. Polymer–matrix composites (PMCs) , B. Environmental degradation , B. Fracture toughness