Title of article :
Modeling of crude oil fouling in preheat exchangers of refinery distillation units
Author/Authors :
Mohammad Reza Jafari Nasr، نويسنده , , Mehdi Majidi Givi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
The aim of this paper is to propose a new model for crude oil fouling in preheat exchangers of crude distillation units. The experimental results of Australian light crude oil with the tube side surface temperature between 200 and 260 °C and fluid velocity ranged 0.25–0.4 m/s were used [Z. Saleh, R. Sheikholeslami, A.P. Watkinson, Heat exchanger fouling by a light australian crude oil, in: Heat Exchanger Fouling and Cleaning Fundamentals and Applications, Santa Fe, 2003]. The amount of activation energy depends on the surface temperature has been calculated. A new model including a term for fouling formation and a term for fouling removal due to chemical and tube wall shear stress was proposed, respectively. The main superiority of the model are independent to Pr number, thermal fouling removal and determination of β based on experimental tests. Finally using the proposed model the fouling rate of Australian light crude oil has been calculated and the threshold curves to identify fouling and no fouling formation zones have been drawn.
Keywords :
Distillation unit , Heat exchanger , Fouling , crude oil , Modeling
Journal title :
Applied Thermal Engineering
Journal title :
Applied Thermal Engineering