Title of article
A thermodynamic analysis of a biogas-fired integrated gasification steam injected gas turbine (BIG/STIG) plant
Author/Authors
R. Layi Fagbenle، نويسنده , , A.B.C. Oguaka، نويسنده , , O.T. Olakoyejo، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
6
From page
2220
To page
2225
Abstract
A thermodynamic analysis considering both the first and the second laws of thermodynamics has been made on a 53 MW (net) biogas-fired integrated gasification steam injected gas turbine (BIG/STIG) plant. The energy utilization diagrams (EUDs) for the plant and for the reaction subsystems have also been considered, revealing both problems and potentials for improvement. The analysis indicates a thermal efficiency of about 41% (power based) and 45% (power and recovered heat based) but that the exergy loss in the combustion chamber is largest at about 79% of the total system exergy loss.
Keywords
Availability-factor , EUD , BIG/STIG , CCGT , BIG/ISTIG , Exergy , Biogas , Second law
Journal title
Applied Thermal Engineering
Serial Year
2007
Journal title
Applied Thermal Engineering
Record number
1041408
Link To Document