Title of article
Influence of different means of turbine blade cooling on the thermodynamic performance of combined cycle
Author/Authors
Sanjay ، نويسنده , , Onkar Singh، نويسنده , , B.N. Prasad، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
12
From page
2315
To page
2326
Abstract
A comparative study of the influence of different means of turbine blade cooling on the thermodynamic performance of combined cycle power plant is presented. Seven schemes involving air and steam as coolants under open and closed loop cooling techniques have been studied. The open loop incorporates the internal convection, film and transpiration cooling techniques. Closed loop cooling includes only internal convection cooling. It has been found that closed loop steam cooling offers more specific work and consequently gives higher value of plant efficiency of about 60%, whereas open loop transpiration steam cooling, open loop steam internal convection cooling, transpiration air cooling, film steam cooling, film air, and internal convection air cooling have been found to yield lower values of plant efficiency in decreasing order as compared to closed loop steam cooling.
Keywords
Combined cycle , Film , Blade cooling , Open and closed loop cooling , Transpiration , Steam cooling
Journal title
Applied Thermal Engineering
Serial Year
2008
Journal title
Applied Thermal Engineering
Record number
1041753