Title of article
Analysis of chimney height for solar chimney power plant
Author/Authors
Xinping Zhou، نويسنده , , Jiakuan Yang، نويسنده , , Bo Xiao، نويسنده , , Guoxiang Hou، نويسنده , , Fang Xing، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
8
From page
178
To page
185
Abstract
Current in solar chimney power plant that drives turbine generators to generate electricity is driven by buoyancy resulting from higher temperature than the surroundings at different heights. In this paper, the maximum chimney height for convection avoiding negative buoyancy at the latter chimney and the optimal chimney height for maximum power output are presented and analyzed using a theoretical model validated with the measurements of the only one prototype in Manzanares. The results based on the Manzanares prototype show that as standard lapse rate of atmospheric temperature is used, the maximum power output of 102.2 kW is obtained for the optimal chimney height of 615 m, which is lower than the maximum chimney height with a power output of 92.3 kW. Sensitivity analyses are also performed to examine the influence of various lapse rates of atmospheric temperatures and collector radii on maximum height of chimney. The results show that maximum height gradually increases with the lapse rate increasing and go to infinity at a value of around 0.0098 K m−1, and that the maximum height for convection and optimal height for maximum power output increase with larger collector radius.
Keywords
Solar chimney , Maximum height , Optimal height
Journal title
Applied Thermal Engineering
Serial Year
2009
Journal title
Applied Thermal Engineering
Record number
1041779
Link To Document