Title of article :
3D numerical and experimental analysis for thermal–hydraulic characteristics of air flow inside a circular tube with different tube inserts
Author/Authors :
Yu-Wei Chiu، نويسنده , , Jiin-Yuh Jang، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
9
From page :
250
To page :
258
Abstract :
Numerical and experimental analyses were carried out to study thermal–hydraulic characteristics of air flow inside a circular tube with different tube inserts. Three kinds of tube inserts, including longitudinal strip inserts (both with and without holes) and twisted-tape inserts with three different twisted angles (α = 15.3°, 24.4° and 34.3°) have been investigated for different inlet frontal velocity ranging from 3 to 18 m/s. Numerical simulation was performed by a 3D turbulence analysis of the heat transfer and fluid flow. Conjugate convective heat transfer in the flow field and heat conduction in the tube inserts are considered also. The experiments were conducted in a shell and tube exchanger with overall counterflow arrangement. The working fluid in the tube side was cold air, while the hot Dowtherm fluid was on the shell side. To obtain the heat transfer characteristics of the test section from the experimental data, the ε-NTU (effectiveness-number of transfer unit) method is applied to determine the overall conductance (UA product) in the analysis. It was found that the heat transfer coefficient and the pressure drop in the tubes with the longitudinal strip inserts (without hole) were 7–16% and 100–170% greater than those of plain tubes without inserts. When the longitudinal strip inserts with holes were used, the heat transfer coefficient and the pressure drop were 13–28% and 140–220%, respectively, higher than those of plain tubes. The heat transfer coefficient and the pressure drop of the tubes with twisted-tape inserts were 13–61% and 150–370%, respectively, higher than those of plain tubes. Furthermore, it was found that the reduction ratio in the heat transfer area of the tube of approximately 18–28% may be obtained if the twisted-tape tube inserts are used.
Keywords :
Thermal–hydraulic characteristics , Longitudinal strip , Twisted-tape inserts
Journal title :
Applied Thermal Engineering
Serial Year :
2009
Journal title :
Applied Thermal Engineering
Record number :
1041788
Link To Document :
بازگشت