Title of article
A run-around heat exchanger system to improve the energy efficiency of a home appliance using hot water
Author/Authors
Jae Sung Park، نويسنده , , Anthony M. Jacobi، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
8
From page
3110
To page
3117
Abstract
A significant portion of the energy consumed by many home appliances using hot water is used to heat cold supply water. Such home appliances generally are supplied water at a temperature lower than the ambient temperature, and the supply water is normally heated to its maximum operating temperature, often using natural gas or an electrical heater. In some cases, it is possible to pre-heat the supply water and save energy that would normally be consumed by the natural gas or electrical heater. In order to save the energy consumed by an appliance using water heater, a run-around heat exchanger system is used to transfer heat from the ambient to the water before an electrical heater is energized. A simple model to predict the performance of this system is developed and validated, and the model is used to explore design and operating issues relevant to the run-around heat exchanger system. Despite the additional power consumption by the fan and pump of the run-around heat exchanger system, the experimental data and analysis show that for some systems the overall energy efficiency of the appliance can be improved, saving about 6% of the energy used by the baseline machine.
Keywords
Water heater , Energy efficiency , Home appliance , Heat exchanger