Title of article
A short note: Effects of fludisation number and total air factor on the Combustion of Municipal solid waste of high moisture content in a fluidised bed
Author/Authors
Anwar Johari، نويسنده , , Haslenda Hashim، نويسنده , , Rozainee Taib، نويسنده , , Ramli Mat، نويسنده , , Mazura Jusoh، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
3
From page
403
To page
405
Abstract
Combustion behaviour of municipal solid waste in a fluidised bed was studied. The effect of fluidisation number and total air factor on the combustion behaviour of municipal solid waste of high moisture content in a fluidised bed combustor was investigated. The first part of the combustion study was carried out at fluidisation numbers ranging from 5 to 7 Umf with a fixed Primary Air Factor (AF) of 0.8. Results show that the optimum fluidisation number is 5 Umf in which the bed temperature sustained longer. The second part of the study dealt with the effect of secondary air on the bed combustion behaviour conducted at 5 Umf. The chosen range of secondary air factor is 0–0.6. It is revealed that the addition of secondary air has no effect on the bed combustion.
Keywords
Fluidisation number , Fluidised bed , Municipal solid waste , Total air factor