  • Abstract
    Combustion behaviour of municipal solid waste in a fluidised bed was studied. The effect of fluidisation number and total air factor on the combustion behaviour of municipal solid waste of high moisture content in a fluidised bed combustor was investigated. The first part of the combustion study was carried out at fluidisation numbers ranging from 5 to 7 Umf with a fixed Primary Air Factor (AF) of 0.8. Results show that the optimum fluidisation number is 5 Umf in which the bed temperature sustained longer. The second part of the study dealt with the effect of secondary air on the bed combustion behaviour conducted at 5 Umf. The chosen range of secondary air factor is 0–0.6. It is revealed that the addition of secondary air has no effect on the bed combustion.
  • Keywords
    Fluidisation number , Fluidised bed , Municipal solid waste , Total air factor