• Title of article

    Experimental investigation of heat transfer and pressure drop in serrated finned tube banks with staggered layouts

  • Author/Authors

    Youfu Ma، نويسنده , , Yichao Yuan، نويسنده , , Yuzheng Liu، نويسنده , , Xiaohong Hu، نويسنده , , Yan Huang، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    10
  • From page
    314
  • To page
    323
  • Abstract
    An experimental study was performed to investigate the heat transfer and pressure drop characteristics of serrated finned tube banks with staggered layouts. The influences of varied fin densities, transversal tube spacing and longitudinal tube spacing were presented. For a constant fin height, an increase in the fin density resulted in an increase in the Euler number, and a gradual decrease in the Nusselt number was observed as the Reynolds number increased. An increase in the transversal tube spacing corresponded to a significant reduction in the Euler number, whereas the Nusselt number essentially remained unchanged. The longitudinal tube spacing had an insignificant effect on the Nusselt and Euler numbers, and the optimum ratio of the transversal tube spacing to longitudinal tube spacing increased with an increase in the transversal tube spacing. Scaling of the tube spacing had little effect on the Nusselt number but had a significant influence on the Euler number. Finally, predictive correlations for Nusselt and Euler numbers were developed based on the data presented here, and comparisons between the test data from this paper and the predictive values from previously published correlations were performed.
  • Keywords
    Serrated fin , Heat transfer , Pressure drop , Heat recovery steam generator , Finned tube
  • Journal title
    Applied Thermal Engineering
  • Serial Year
    2012
  • Journal title
    Applied Thermal Engineering
  • Record number

    1046026