Title of article :
A VALIDATION OF CONVENTIONAL PROTECTION DEVICES IN PROTECTING EMP THREATS
Author/Authors :
S. M. Han، نويسنده , , C.-S. Huh، نويسنده , , and J.-S. Choi ، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2011
Abstract :
The performance of complementary ESD/Lightning protection devices being exposed to EMP was studied. We studied protection devices such as GDT (Gas Discharge Tube), TVS (Transient Voltage suppressor), and Varistor. The EMP signal has a very fast rise time of 100 psec and the maximum peak voltage of 2 kV. The GDT could not protect the EMP signal. The varistor showed about 35% of protection ability, and the TVS showed about 50% of protection ability. Thus the GDT is not a proper device to protect EMP. However, all of the protection devices did not show their nonlinear property.
Journal title :
Progress In Electromagnetics Research
Journal title :