Abstract :
This paper establishes the minimum sustaining voltage, associated current, and minimum sustaining current specifications for a pulsed-vortex-water-wall high-pressure argon arc lamp. The specifications are formulated as a function of the arcʹs pressure and the enclosureʹs length and radius. Patankarʹs control volume algorithm along with boundary conditions has been used to solve the extended Ellenbass-Heller equation in cylindrical coordinates. The simulation results agree qualitatively with previously published experimental results along with the results presented in this paper. The addition of the convection term to Patankarʹs algorithm and a more exact treatment of the radiation term will improve the accuracy of the results.