Title of article :
Synthesis of porous titanium implants by environmental-electro-discharge-sintering process
Author/Authors :
Y.B. An، نويسنده , , Peter W.H. Lee، نويسنده ,
Issue Information :
دوهفته نامه با شماره پیاپی سال 2006
Pages :
6
From page :
242
To page :
247
Abstract :
Porous Ti implants with various porosities were first fabricated by environmental-electro-discharging-sintering (EEDS) of atomized spherical Ti powders. Powders in two size range (50–100 and 200–250 μm) were settled by vibration into a quarts tube and subjected to a high voltage and high density current pulse. A single pulse of 0.75–2.0 kJ/0.7 g-powder, using 150, 300 and 450 μF capacitors, was applied to produce fully porous and porous-surfaced Ti implant compacts. The solid core was automatically formed in the center of the compact after discharge and porous layer consisted of particles connected in three dimensions by necks. The solid core and neck sizes increased with an increase in input energy and capacitance. On the other hand, pore volume decreased with increased capacitance and input energy due to the formation of a solid core. Capacitance and input energy are the only controllable discharge parameters even though the heat generated during a discharge is the unique parameter that determines the porosity of compact. It was shown that EEDS of spherical Ti powders can efficiently produce fully porous and porous-surfaced Ti implants with various porosities in short times (<400 μs) by manipulating the discharging conditions such as input energy and capacitance including powder size.
Keywords :
Biomaterials , Implant , Sintering , Porosity , Electro-discharge
Journal title :
Materials Chemistry and Physics
Serial Year :
2006
Journal title :
Materials Chemistry and Physics
Record number :
1064059
Link To Document :
بازگشت