Title of article :
Detailed analysis of closed-loop control of output-voltage harmonics in voltage-source inverters
Author/Authors :
A.، Garcia-Cerrada, نويسنده , , P.، Roncero-Sanchez, نويسنده , , P.، Garcia-Gonzalez, نويسنده , , V.، Feliu-Batlle, نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
10
From page :
734
To page :
743
Abstract :
The design and application of selective controllers for voltage-source-inverter output control in single-phase and three-phase applications are investigated. It is shown how this type of controller can be used (a) to minimise the effects of the inverter dead times on output-voltage harmonics and (b) to provide flexible control of the inverter low-frequency output-voltage harmonics. The closed-loop stability of the resulting systems is investigated thoroughly and the controller design process is explained from the frequency-response viewpoint where stability margins can be designed explicitly. It is clearly demonstrated that a compromise has to be reached between transient-response speed and tracking (or rejection) accuracy. The main contributions are illustrated with a three-phase prototype, in which the two applications proposed for this type of controller are tested.
Keywords :
Hydrograph
Journal title :
IEE Proceedings Electric Power Applications
Serial Year :
2004
Journal title :
IEE Proceedings Electric Power Applications
Record number :
106487
Link To Document :
بازگشت