Abstract :
Three-dimensional numerical simulations were carried out for mixed convective flows over a backward-facing step in a rectangular duct. Reynolds number, expansion ratio and aspect ratio were kept constant at Re = 125, ER = 2 and AR = 16, respectively. Heat flux at the wall downstream of the step was kept uniform, while other walls were kept at adiabatic condition. Effect of the inclination angles, θ1, θ2, was the main objective in this study. It was found that when θ1 was varied, the effect of buoyancy became prominent at θ1=0°, 180°, while the effect was relatively small for the two horizontal cases (θ1=90°, 270°). However, there was still small difference between θ1=90° and 270° in the region immediately after the step where the flow was relatively slow. When θ2 was varied, flow and thermal fields became asymmetric about the duct centerline, except when θ2=0°, 180°. The maximum Nusselt number, which appears symmetrically near the side walls in pure forced convection cases, was obtained at only one location close to the lower side wall.
Keywords :
Backward-facing step , Numerical simulation , Low Reynolds number , Mixed convection , Inclination angle
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year :
2000
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number :
1069950
Link To Document :
بازگشت