Title of article
Dry patch interaction caused by lateral conduction in transition boiling
Author/Authors
L.H Chai، نويسنده , , M Shoji، نويسنده , , X.F. Peng، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
5
From page
4169
To page
4173
Abstract
The present paper analyzed the temperature fluctuation correlation caused by lateral heat conduction in heater in transition boiling system and derived the critical temperature fluctuation space correlation length, within which dry patches might interact to result in the occurrence of stable film boiling regime. The mechanism for non-hydrodynamic transition was revealed. The present investigation not only provided comprehensive and rational insights on transition boiling mechanisms, but also might find important industrial applications.
Keywords
Dry patch , Film boiling , Transition boiling , Temperature fluctuation correlation