Title of article
Measurement of endwall heat transfer and pressure drop in a pin-fin wedge duct
Author/Authors
Jenn Jiang Hwang، نويسنده , , Chau-Chin Lui، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
13
From page
877
To page
889
Abstract
This paper discusses the measurements of endwall heat transfer and pressure drop in a wedge-shaped duct inserted with an array of circular pin fins. The endwall surface is coated with a thin layer of thermochromic liquid crystals and a transient test is run to obtain detailed heat transfer distributions. Parametric studies include Reynolds number (10,000⩽Re⩽50,000), outlet flow orientation (straight and lateral) and pin configuration (staggered and in-line). The wedge duct has a convergent angle of 12.7°. The pin spacing-to-diameter ratios along the longitude and transverse directions are fixed at sx/d=sy/d=2.5. Pin-less wedge duct results are also obtained for comparison. Results indicated that the straight wedge duct with a staggered pin array is most recommended because of its significant endwall heat transfer and moderate pressure-drop penalty; while the turned wedge duct with a staggered pin array is least recommended since it yields the highest pressure drops and raises severe hot spots. A similarity of the pin Reynolds-number dependence of row-averaged Nusselt number is developed in the present wedge duct of accelerating flow.
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2002
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
1070751
Link To Document